Testlab Test & solution

Shield Room

EMC Testing

  • シールドルーム
  • ISO11452-4 (BCI)

    ISO11452-4(BCI)
  • ISO11452-8 (M-I magnetic field)

    ISO11452-8(M-I magnetic field)
  • ISO10605 (ESD)

    ISO10605(ESD)
Target Test Feature Frequency Range Test Method Test Level Modulation Method Test Room(m)
W × D × H
Measurement Room(m)
W × D
Monitoring
・BCI
・ESD
・M/I magnetic field
・Square wave noise test
・Transient emissions
・Transient immunity
・Voltage fluctuation
ISO11452-4 and compliant with vehicle manufacturer standards 10 kHz- 2.1 GHz ISO11452-4 BCI method 200 mA CW, AM, PM 3.8
×
4.4
×
3.0
5.0
×
3.8
2
ISO10605 and compliant with vehicle manufacturer standards ISO10605 ESD ±30 kV
ISO11452-8 and compliant with vehicle manufacturer standards 15 Hz – 150 kHz ISO11452-8 M/I magnetic field Level 4
Compliant with vehicle manufacturer standards Impulse test ±4 kV
ISO7637, ISO16750
Compliant with vehicle manufacturer standards
Transient emissions /
Immunity /
Voltage fluctuation