A45/EM4HAM
Chamber Combined Vibration and Shock Test System
Features | Frequency Range (Hz) |
Rated Force | Maximum Acceleration | Maximum Velocity | Maximum Displacement | Maximum Load (kg) |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Sine (kN) |
Random (kN rms) |
Shock (kN) |
Sine (m/s2) |
Random (m/s2 rms) |
Shock (m/s2 peak) |
Sine (mmp-p) |
Shock (m/s peak) |
Sine (mmp-p) |
Maximum Travel (mmp-p) |
|||
High velocity shock test IEC60068-2-6, 27, 64 compliant ISO19453 compliant Large horizontal excitaiton chamgeover type |
2600 | 45 | 45 | 90 (80) | 720 | 504 | 1440 | 2.0 | 2.5 (3.5) | 76.2 | 82 | 600/931 |
Slip Table
Size (mm) | Pitch Moment |
---|---|
750 × 750 | M10 × 100 mm |
Chamber
Internal Size W × D × H (mm) | Temperature Range (℃) | Temperature Range Rate (℃/min) | Humidity Range (% RH) |
---|---|---|---|
1000 × 1000 × 1000 | -70 to +180 | 1.3 | 20 to 98 |