Case study Case Studies

Lithium battery temperature and vibration combined charge-discharge test

  • Vibration test case study
  • Battery
  • Random

Test overview

■ Purpose

To check the functional performance of lithium batteries installed in electric and hybrid vehicles in a combined temperature and vibration environment for charging and discharging.
*Customers using our laboratory are assumed to use a safety device and to use a system that immediately stops testing in the event of a battery malfunction.

■ EUT

8-cell lithium battery, W190 × D200 × H120 mm (2 sets of 4 cells), 13 kg/piece (mass of fixture: 30 kg)

■ Test conditions

Test time: 20 hours/direction
*The charge/discharge test shall be started 1 hour after the temperature reaches minus 40°C.

IEC 16750-4 Ref / IEC 62660-2 Ref

Test state image

Memo

Facilities used

Vibration test system: i230/SA3M
Constant temperature and humidity chamber: IMV-05111
Vibration controller: K2 software Random
Head expander: TBV-550S-J50

Test time

10 hours