Case study Case Studies

Transport test 4

  • Vibration test case study
  • JIS standard
  • Transportation tests
  • Random

Test overview

■ Purpose

To ensure that cargo is properly packaged.

■ EUT

Packing (precision equipment in cardboard packaging) 482 mm × 330 mm × 221.5 mm, 18 kg, 1 piece

■ Test conditions

Transport test (JIS Z 0232)] PSD in JIS Z 0232 Annex A Table 1 Test duration 30 min
Drop test (JIS Z 0200)] Total mass: 10 kg or more but less than 20 kg Level I / Drop height: 600 mm / Drop location: 1 corner, 3 ridges, 6 sides.
*Conducted in the 2004 edition.

Figure 1: JIS Z 0232 Annex A Random vibration PSD

Random vibration test

Drop test

Memo

Facilities used

Vibration test system: i220/SA2M/H6

Vibration controller: K2 software Random
Vibration test system: DLJ-150 (packaging drop test system)

Test time

12 hrs.
(i220/SA2M/H6, 6h + DLJ-150, 6h)