G-0235L(P)
Chamber combined vibration test system
Room Number | Feature | Frequency Range (Hz) |
Rated Force | Maximum Acc. | Maximum Vel. | Maximum Disp. (mmp-p) |
Armature Mass(kg) | Maximum Load |
Allowable Eccentric Moment (N・m) |
Shaker Body Diameter (mm) |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sine (kN) |
Random (kN rms) |
Shock (kN) |
Sine (m/s2) |
Random (m/s2 rms) |
Shock (m/s2 peak) |
Sine (m/s) |
Shock (m/s peak) |
||||||||
B2, B3 | ISO 19453 compliant, GB standard compliant |
2000 | 34.3 | 24 | 51 | 1000 | 595 | 1538 | 2.0 | 2.0 | 51 | 33 | 300 | 980 | Φ360 |
Chamber
Room No. | Internal Dimensions W × D × H(mm) | Temperature Range(℃) | Temperature Range of Change(℃/min) | Humidity Range(% RH) |
---|---|---|---|---|
B3 | 1000 × 1000 × 1000 | -40 to +180 | 0.67 | 20 to 98 |
B2 | 1500 × 1500 × 1500 | -40 to +180 | 0.67 | 20 to 98 |