Vibration Sensors
Electrodynamic Velocity Sensor
Principle of reciprocal pendulum type sensor is to induce voltage by reciprocal
motion of the seismic mass with a coil in the magnetic field being suspended
by a diaphragm or coil spring.
-
Principle of reciprocal pendulum type sensor is to induce voltage by reciprocal motion of the seismic mass with a coil in the magnetic field being suspended by a diaphragm or coil spring. Because of its high sensitivity and advanced linearity, it is suitable for detection of malfunction or deterioration of rotational machineries. Due to its structure, mounting should be done carefully for its direction or angle.
Features
High sensitivity, stable performance, advanced linearity in wide amplitude range
Relatively large output
Because of small internal resistance, long cable can be used.
External power supply is not necessary (self – power generation)
Suitable for sleeve bearing vibration measurement
Frequency response
The upper frequency limit is to be difined by the response of the low-pass filter. The lower frequency limit depends on its own natural frequency. Use in the frequency range lower such frequency is possible by damping the peak of the resonance.
Fixing Methods
Fixing angle
The table below shows the fixing angle of sensor whose natural frequency is 14 Hz or 4.5 Hz.
Fixing direction
Both (a) and (b) are available for the sensor whose natural frequency is 14 Hz, but the sensor whose natural frequency is 4.5 Hz is limited to any one of the (a) or (b). Can not be fixed downwardly. Special fixture is needed to fix upwardly.
Difference between C and D
The difference between C and D is the shape of cable connection.