News Unternehmens-Neuigkeiten

Latest Addition to IMV’s Product Range -350 kN Water Cooled Shaker-

IMV CORPORATION has added a new water cooled shaker to the impressive K-series range, with a force rating of 350 kN.
The world premium K-series class K350 has a displacement of 76.2 mm p-p and a shock velocity rating of 3.5 m/s.
This makes the K350 capable of a 100 g, 11ms shock pulse with exceptional force rating.
The K350 is available with IMV’s award winning eco-technology.

Specifications

  System Model K350/SA50HM
  Frequency Range(Hz) DC–2000 *No load-3000
System
Specifications
Rated
Force
Sine(kN) 350
Random (kN rms)*1 315
Shock(kN) 700
Maximum
Acc.
Sine(m/s2) 1000*4
Random (m/s2 rms) 700
Shock (m/s2 peak) 2000
Maximum
Vel.
Sine(m/s) 2
Shock
(m/s peak)
3.5
Maximum
Disp.
Sine(mmp-p) 76.2
Maximum Travel (mmp-p) 94
Maximum Load(kg) 3000
Power Requirements (kVA)*2 420
Vibration
Generator
Model K350
Armature Mass(Kg) 350
Armature Diameter(φmm) 760
Allowable Eccentric Moment(N・m) 4900
Dimensions(mm) WxHxD 3020x2306x2080
Shaker Body Diameter(mm) 1630
Mass(kg) 37000
Power
Amplifier
Model SA50HM-K350
Maximum Output(kVA) 400
Dimensions(mm) WxHxD 4640x1950x850
Mass(kg) 6200

*1) Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
*2) Power supply: 3-phase 380/400/415/440 V, 50/60 Hz. A transformer is required for other supply voltages.
*3) If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 1.4 m/s.
*4) 700 m/s2 is recommended for durability test
* The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure.
* In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
* Frequency range values vary according to sensor and vibration controller.