Latest Addition to IMV’s Product Range -350 kN Water Cooled Shaker-
IMV CORPORATION has added a new water cooled shaker to the impressive K-series range, with a force rating of 350 kN.
The world premium K-series class K350 has a displacement of 76.2 mm p-p and a shock velocity rating of 3.5 m/s.
This makes the K350 capable of a 100 g, 11ms shock pulse with exceptional force rating.
The K350 is available with IMV’s award winning eco-technology.
Specifications
System Model | K350/SA50HM | ||
---|---|---|---|
Frequency Range(Hz) | DC–2000 *No load-3000 | ||
System Specifications |
Rated Force |
Sine(kN) | 350 |
Random (kN rms)*1 | 315 | ||
Shock(kN) | 700 | ||
Maximum Acc. |
Sine(m/s2) | 1000*4 | |
Random (m/s2 rms) | 700 | ||
Shock (m/s2 peak) | 2000 | ||
Maximum Vel. |
Sine(m/s) | 2 | |
Shock (m/s peak) |
3.5 | ||
Maximum Disp. |
Sine(mmp-p) | 76.2 | |
Maximum Travel (mmp-p) | 94 | ||
Maximum Load(kg) | 3000 | ||
Power Requirements (kVA)*2 | 420 | ||
Vibration Generator |
Model | K350 | |
Armature Mass(Kg) | 350 | ||
Armature Diameter(φmm) | 760 | ||
Allowable Eccentric Moment(N・m) | 4900 | ||
Dimensions(mm) WxHxD | 3020x2306x2080 | ||
Shaker Body Diameter(mm) | 1630 | ||
Mass(kg) | 37000 | ||
Power Amplifier |
Model | SA50HM-K350 | |
Maximum Output(kVA) | 400 | ||
Dimensions(mm) WxHxD | 4640x1950x850 | ||
Mass(kg) | 6200 |
*1) Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
*2) Power supply: 3-phase 380/400/415/440 V, 50/60 Hz. A transformer is required for other supply voltages.
*3) If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 1.4 m/s.
*4) 700 m/s2 is recommended for durability test
* The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure.
* In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
* Frequency range values vary according to sensor and vibration controller.